- Photos & Details
- Specifications
Product overview:
● Network address modules are available in single-zone and dual-zone versions.
The single-zone network address module includes: 1 signal detection input and 1 relay output.
The dual-zone network address module includes: 2 signal detection inputs and 2 relay outputs.
● The network address module has a built-in network port and can be configured with 4 network centers; all network parameters of the module can be configured remotely through configuration software.
● It has a built-in address code (zone ID) switch for convenient user operation.
● Each zone of the module can be individually armed and disarmed.
● It is highly compatible and can connect to all alarm devices with relay output (such as Laser Beam Detectors, Infrared Beam Detectors, infrared detectors, Smoke Alarm detectors, Gas Alarm detectors, emergency buttons, magnetic contacts, curtain detectors, fire alarms, Electronic Fences, Tension Electronic Fences, high-voltage electric grids, etc.).

Indicator description:
1. System lamp status:
Red lamp off: the zone is disarmed and does not respond to input alarms.
Red lamp on: the zone is armed.
2. Network port lamp status:
Network port lamp flashing: network communication is normal.
Network port lamp steadily off: network cable is not plugged in or the connection is abnormal.
技术参数:
型号:AT-D100-2S
● 工作电压: DC12V
● 工作电流: 74mA
● 使用环境: 温度:-30~+60℃ 湿度:≤95%
● 网 口: RJ45,10M/100M自适应
● 检测输入信号: 开关量常闭信号(NC)和公共端(COM)
● 报警输出信号: 开关量常开信号(NO)和公共端(COM)
● 外观尺寸: 92*78.4*25mm
Please contact us right away or call the hotline: +86-13590284141. We will answer all your questions in detail. Project Manager Online